Misplacement of an internal jugular hemodialysis catheter...

Misplacement of an internal jugular hemodialysis catheter due to stenosis caused by previous short-term catheterization


Department of Anesthesiology and Critical Care Medicine, Indira Gandhi Institute of Medical Sciences, Patna, India

Dual lumen hemodialysis catheters are usually inserted via the right internal jugular vein (IJV). Subclavian vein (SCV) is generally avoided to prevent thrombosis or narrowing. [1] The site of stenosis caused by SCV catheter is usually near the junction of the SCV and IJV. [2]

A 30-year-old female, suffering from endstage renal disease, was in the operating room for insertion of a hemodialysis catheter. She had undergone right IJV catheterization about 45 days back. The previous catheter had remained in situ for about 15 days. The exact cause of catheter removal was not documented. As she had no clinical signs or symptoms in the upper limb or the neck suggesting any complication, it was decided to cannulate the right IJV again.

After instituting monitoring with lead II electrocardiogram, noninvasive blood pressure, and a pulse oximeter, a 12.5 Fr hemodialysis catheter (Soft-cell® PC kit, Bard Access Systems, Utah, USA) was placed uneventfully via the right IJV under local anesthesia with full aseptic precautions. Free aspiration of blood via both the lumens was attained through a 5-ml syringe. A chest radiograph was obtained postprocedure and haemodialysis was started without inspecting the X-ray film. However, a satisfactory blood flow through the hemodialysis machine could not be obtained. Gentle manipulation of the catheter and change in patient position made no difference to the flow. Meanwhile, the X-ray film revealed catheter misplacement into the ipsilateral SCV [Figure 1].

Read full article here

Friday, June 11, 2010

Lighter moments....

An old man was driving on the freeway when his mobile phone rang. It was his wife..."Herman" she cried "I just heard on the news that there's a car going the wrong way on 280. Please be careful"

"Hell" exclaimed Herman..."Its not just one car. Its hundreds of them!"

Sunday, June 6, 2010

Refusing To Continue Dialysis....

The Women Who Did Not Mean “NO”

By Michael Blumenfield, M.D

A case history
An 82 year old Italian speaking grandmother with a very dedicated and loving large family was coming to the hospital three times a week to receive hemodialysis for kidney failure. This is a four or five hour process where tubes are attached to her blood vessels through a special connection called a fistula and her blood is run through a machine with a filter system to clean it of toxins since her kidneys are not functioning properly. She was viewed as having been depressed for approximately two years and frequently would be reluctant to come for her dialysis. She was on Prozac, an antidepressant, for about one year with no apparent change.

Recent Complication
Most recently the patient’s fistula clotted and there were no more readily available sites to reconnect the equipment. Surgery was recommended to create a new vascular site for the dialysis but the patient refused to go along with this procedure. The family explained that she had suffered enough and now just wanted to stop the dialysis and peacefully pass away.

Read full article here

Friday, June 4, 2010

Defibrillation during renal dialysis

Defibrillation during renal dialysis: A survey of UK practice and procedural recommendations

By Scot Birda, Graham W. Petleyb, Charles D. Deakina & Frank Clewlowb
http://www.resuscitationjournal.com/article/S0300-9572(06)00668-X/abstract

Abstract

Introduction
Defibrillation of patients connected to medical equipment that is not defibrillation proof risks ineffective defibrillation and harm to the operator as a result of aberrant electrical pathways taken by the defibrillation current. Many renal dialysis systems are not currently defibrillation proof. Although national and international safety standards caution against defibrillating under this circumstance, it appears to be an area of confusion that we have investigated in more detail.

Methods
Thirty renal dialysis units across the UK were invited to participate in a telephone survey of current practice from 1 October 2004 to 1 October 2005. The Medical Healthcare Regulatory Agency and renal dialysis machine manufacturers were contacted for advice, and current safety standards were reviewed.

Results
Twenty-eight renal dialysis units completed the survey. Seven (25%) units would not disconnect patients from dialysis equipment during defibrillation, collectively reporting 14 patients who had required defibrillation during dialysis. Eighteen (64.3%) units would disconnect patients from dialysis equipment during defibrillation, collectively reporting 29 patients who had required defibrillation during dialysis. No complications were identified by this survey, through the MHRA or through a literature search.

Conclusion
Defibrillation of patients while undergoing renal dialysis is common practice in the UK. Although no adverse events have been reported, this practice risks injury to the patient and clinical staff, and equipment damage if the dialysis equipment is not defibrillation proof. It is in breach of national and international safety standards and should not be practiced.

Wednesday, June 2, 2010

Facial protection....

Facial protection in renal dialysis units: a literature review

By Lorraine Bublitz, Renal Society of Australasia Journal, Nov. 2005

Abstract

Aim The aim of this paper is to raise awareness and critically evaluate the need for greater facial barrier protection, in order to reduce the frequency of mucocutaneous exposure for health care workers in renal dialysis units (RDU).

Method A literature review of published literature related to the use and application of standard precautions was conducted, focusing on facial barrier protection for health care workers (HCW) in various health care settings.

Findings Despite renal dialysis nurses having considerable risk of permucosal (splash) contamination the overwhelming literature discusses this exposure in a variety of other health care settings. HCW level of compliance to standard precautions, particularly the use of personal protective equipment (PPE) requires significant improvement. There is an urgent need for PPE to be more suitable and easily accessible to the HCW in order to prevent interference with patient procedures, and promote compliance of standard precautions.

Conclusion The literature confirms that HCW in RDU are at risk of exposure to blood borne infections. HCW rarely fully implement and comply with standard precautions in regards to application of PPE in various health care settings however further research is required to determine compliance in renal dialysis units. Facial barrier protection requires significant and urgent redesign in suitability, safety and accessibility in order for HCW to fully embrace its use.